Product Features :
Coated titanium anode for impressed current cathodic protection—MMO active coated titanium anode uses titanium as the substrate, and adopts thermal decomposition method to form oxide coating of platinum group metals.
1. Light weight and good chemical stability, even in low pH value and environment containing chloride ions, it also has good chemical stability;
2. Dimensions are stable within the design life of the anode;
3. Uniform coating loss rate, 1-6mg/A.a;
4. Can work at high current density, 2000A/m²;
5. Electrical conductivity, 10-7Ω·m.

Coating type :
Number | Coating Type | application |
---|---|---|
1 | Ru-Ir-Ti | Anti-corrosion materials for seawater environment Ocean bridge anti-corrosion |
2 | Ir-Ta | Soil Backfill Freshwater Tank Protection Home Construction |
Anode classification :
1 : Titanium Wire Anode
Pure titanium wire: size and performance conform to ASTM standard B348 grade 1 and grade 2.
Application:Continuous horizontal ground bed, discontinuous horizontal ground bed, shallow buried vertical ground bed, ground storage tank, underground storage tank, cable protection, water storage tank, water treatment equipment .

Dia (MM) | Length | Input Current -MA/m |
---|---|---|
1.5 | 300m | 328 |
3.0 | 300m | 656 |
2: Titanium Strip anode
Substrate material: titanium strip conforms to ASTM standard B265 grade 1 and grade 2
Coating type: IrO2-TaO5-X
Pure titanium wire: size and performance conform to ASTM standard B348 grade 1 and grade 2.
Application:
Strip-shaped titanium anodes are often made into a grid shape Anodes are easily cut off and thus can be used for cathodic protection of tank floors of all areas,Uniform current distribution ,Excellent performance when used in reinforced concrete structures and has a good bond with concrete
Anode strip spacing can be adjusted to achieve the required design life

Width | Thickness | Length | input current MA/m |
---|---|---|---|
6.35 | 0.635 | 152 | 17 |
12.7 | 0.635 | 152 | 34 |
2: Titanium Rod Anode
Substrate material: Titanium rod conforming to ASTM standard B348 grade 1 and grade 2
Coating type: choose different types according to the medium used in cathodic protection 2.
Application:
Condensate tank, heat exchanger, floor bed
High current output, constant resistance, not affected by surge current, can withstand higher current overload during initial polarization without damaging the anode

Dia (mm) | Length mm | weight | m² |
---|---|---|---|
3.2 | 1000 | 0.036 | 0.01 |
6.4 | 1000 | 0.145 | 0.02 |
12.7 | 1000 | 0.57 | 0.04 |
19 | 1000 | 1.257 | 0.06 |
2: Titanium Mesh anode
Substrate material: Titanium mesh conforms to ASTM standard B265 grade 1 and grade 2
Coating type: choose different types according to the medium used in cathodic protection
Application:
It can be made into a cylindrical shape to replace ferrosilicon anodes. Reinforced concrete cathodic protection bridge piers and bridge decks
Parking lot, flood embankment, pier

2: Titanium Tube anode
Substrate material: ASTM standard B338 grade 1 and grade 2
Coating type: choose different types according to the medium used in cathodic protection
Application:
Tubular anodes can be used individually or as anode strings
Can be used in all natural environments, such as: soil, fresh water, sea water, mud, etc.
Current output depends on anode size, substrate, application, and design life
The larger the specific surface area, the larger the current output and the smaller the anode grounding resistance
Tubular anode can save 15-35% installation cost compared with other anodes
The unique flexibility of tubular anodes facilitates handling, transportation and installation
Anode/cable resistance less than 0.001ohms
Standard coating amount anode guaranteed life of 20 years

Out-Dia (mm) | Thickness (mm) | Length(mm) | Weight (kg) | m² |
---|---|---|---|---|
19 | 1 | 1200 | 0.3 | 0.072 |
25 | 1.5 | 500 | 0.25 | 0.039 |
25 | 1.5 | 1000 | 0.5 | 0.079 |
25 | 1.5 | 1200 | 0.6 | 0.094 |
25 | 1.5 | 1500 | 0.75 | 0.118 |
31 | 2 | 1200 | 1 | 0.121 |